In electroplating and electrophoresis industry, the bath solution generates heat irregularly under high frequency reaction, so the bath solution temperature rises gradually. When the electroplating solution temperature exceeds the process requirements, it has a great impact on the firmness, uniformity, flatness and surface finish of the product surface coating. The water chiller helps stabilize the metal and non-metallic ions, make the metal ions attach to the surface of the plating part, increase the density and smoothness of the plating part, shorten the plating period, improve the production quality, reduce the loss of plating raw materials and recover the chemical substances, cool and maintain the constant temperature of the plating solution, which will greatly improve the production process, product quality and production efficiency.
Plating water chilling unit can be divided into galvanized water chilling unit, tinned water chilling unit, nickel plating water chilling unit, chromium plating water chilling unit, copper plating water chilling unit, gold plating water chilling unit, silver plating water chilling unit and vacuum coating water chilling unit according to different electroplating materials and types.
It can be divided into direct cooling type and intercooling type according to different cooling modes.
Compressor: Fully-enclosed flexible scroll compressor is adopted, with simple structure, no wear of compression parts, small torque change, high balance, energy conservation and stability, easy operation and automatic control;
Shell and tube condenser: the external thread copper tube is used, CAD/CAM design and processing technology is used, and the production is completed in cooperation with the CNC processing center. The effective heat transfer area is calculated according to the corresponding heat dissipation, water flow velocity and fouling coefficient, with 5-10% margin left; The end covers on both sides are easy to disassemble and maintain;
Evaporator: the steel-plastic composite shell coil heat exchanger is adopted, the heat exchange tube is the rifled tube, which is the high and new small channel product developed by the heat transfer enhancement technology. The tube arrangement mode makes the heat transfer coefficient reach the current level of the heat exchanger field, which can improve the operation efficiency of the unit. The shell is steel-plastic composite, and the contacted water surface is sealed engineering plastic, with strong corrosion resistance and long service life. No internal and external cracks are found in the design structure after several freezing tests, so the anti-freezing performance is excellent. The enclosure is removable for easy maintenance and cleaning.
Anti-corrosion unit: anti-corrosive evaporator is adopted, direct cooling method without any secondary heat exchange equipment, energy saving more than 36% compared with ordinary unit, shorter cooling time, more accurate temperature control, energy saving.
Anti-corrosion fins of air cooled heat exchanger: anti-corrosion hydrophilic aluminum foil and secondary flanging and tube expanding process are adopted, so the copper tube and fins are more closely contacted and the heat exchange efficiency is high. There is no need to install additional cooling water pump and water tower, which is characterized by reliable operation, convenient cleaning, strong cooling capacity, low noise, long service life, simple and convenient operation. It is especially suitable for areas with lack of water resources or high hardness of water quality.
Control system: industrial centralized control system, full Chinese operation interface, convenient menu prompt operation, can check the operation state of the unit at any time, adjust the working mode, accurately control the matching between the refrigerating capacity and cooling load of the unit, ensure the unit operates with normal efficiency and reduce the operation cost. It integrates multiple protection functions such as water flow, low temperature, high and low pressure, anti-freezing, reverse phase loss, delay start, overload, overtemperature and oil pressure difference. The accurate control can control the temperature within ± 1 ℃, which is convenient and reliable for operation.
Electrostatic plastic spraying shell, fully enclosed box structure, beautiful appearance.
The after-sales service takes the improvement of customer satisfaction as its own principle and solemnly promises:
The company has established a complete data file for the sold products, and has a capable after-sales team to provide 24-hour service and excellent after-sales service
Provide a complete application and design scheme integrating equipment selection, site design, engineering installation and after-sales service according to the actual needs of users.
We will solve technical problems for you at any time, and the company will pay regular return visits to the use of equipment; The after-sales service team will inspect irregularly and take preventive measures to make you experience satisfactory service quality.
Carry out timely after-sales repair and maintenance service in strict accordance with after-sales service terms. The free warranty period is one year. Within the warranty period, the maintenance of spare parts is free of charge.
Lifelong maintenance: if the equipment fails after the warranty period expires, the damaged accessories shall be charged at the cost only.
National free service hotline: 400-600-8096 |